EnergyWise
How it works

From a power cut to a diesel number — in four steps.

No new fuel-flow sensor, no genset retrofit. Our AI infers the burn from the electricity we already measure and the way your set actually behaves.

01

Detect the cut

We watch the mains at your panel. When voltage and frequency drop, we timestamp the outage — start, end, exact duration.

grid down · DG on
02

Rebuild the load

The meter can't read draw during a total outage, so the AI reconstructs it: your typical load for that same weekday and time window, learned from prior weeks.

same-window baseline
03

Model the burn

The AI applies your genset's fuel curve — adjusted for its age and how hard it's loaded — to turn kWh delivered into litres of diesel.

L = kWh × L/kWh
04

Reconcile & flag

We line the estimate up against what your fuel log says was filled. Every unexplained litre — and every oddity — gets flagged.

estimate vs reality

Honest maths, not a spec sheet.

A brand-new genset near full load sips about 0.27 litres per kWh. Yours isn’t new, and it rarely runs at full load. Two things quietly push the real number up:

  • Age. Every year of wear adds roughly 1% to fuel per unit — an old set is thirstier than its rating claims.
  • Part-load. Run a big set lightly loaded and efficiency collapses — 'wet stacking' burns fuel for nothing.

The AI bakes both into every estimate, so the litres we expect match the litres your set really drinks. The gap that’s left isn’t the engine — it’s diesel that was siphoned, short-filled or logged against a cut that never happened.

Priced to your set, not a spec sheet
L / kWh

The fuel-per-unit we expect, tuned to your set’s age

0.270.290.310 yr4 yr8 yr12 yryour set · 8 yr
What we flag

When the litres don’t add up, you know that day.

Not a month-end surprise buried in a spreadsheet. As soon as consumption drifts from what your outages and load can justify, EnergyWise raises it.

Fuel reconciliation
Last 7 days · 750 kVA standby DG
Tracking
Diesel we can’t explain
₹8,096· 88 L · +20%
Estimated need432 L
Actually filled520 L
3 outages
4.2 h on DG
₹39,744
expected diesel cost
+29 L

Fuel drawn beyond the run

Saturday's fill outran the diesel that runtime and load can justify by 29 litres — the classic signature of pilferage.

42 min

Runtime with no outage

42 minutes of generator runtime while the mains supply stayed healthy throughout — fuel burned off the record.

45 min

A cut that never happened

A 45-minute outage sits in the register, but the meter shows the site drawing from the grid the whole time.

+40 L

Refuel with no hours to match

A diesel fill logged against runtime the generator never clocked — consumed on paper, not in the tank.

Get started

See your own diesel, reconciled.

Book a short walkthrough on sample data, or send your genset details and we’ll run your first reconciliation. Either way you’ll see exactly where the litres go.

  • 20 minutes, on a real facility's data
  • No genset retrofit, no fuel sensor
  • Talk to an engineer, not a call centre

Run my reconciliation

We reply within one business day.

No spam. Your details are only used to prepare the walkthrough.